Separation Laboratory and environmental samples often have particles that differ a lot in size. For instance a water sample might include bits of debris, sediment, tiny biological bits and other small suspended particles. Biological samples can also have cell clusters or spheroids that vary in size.

When the aim is to divide these particles into groups using just one mesh for the entire sample may not offer enough precision. A mesh keeps particles that're larger than a certain size and lets smaller ones pass through. This works fine if the particles are mostly similar in size.. When a sample has both large and small particles a single mesh can cause particles of different sizes to end up in the same group.

Multi-stage filtration gives control. Of using just one mesh the sample goes through several meshes, each, with a different opening size. Each stage catches particles based on their size. This allows the sample to be split into fractions during the same filtration process.

The pluriStrainer® Maxi is designed to support this type of large-volume filtration. Mesh sizes are available in 13 options starting from 5 µm, up to 2,000 µm. These mesh sizes can be stacked together to form a -stage filtration setup. A multi-stage filtration setup helps researchers create a separation workflow that fits the sample they are working with. It also helps them gather the fractions they need. For laboratories that handle sample volumes using multi-stage filtration makes particle separation more organized. By passing the sample through filtration devices several times researchers can arrange various mesh sizes in a specific order. This method gives control over how particles are separated based on size. This way they can collect particle fractions as the sample flows through each stage. The value of multi‑stage filtration is therefore not simply that it uses more than one mesh. Its main advantage is that it introduces several defined separation points into one workflow.

How Multi-Stage Filtration with pluriStrainer® Maxi Works

Multi-stage filtration separates particles progressively according to their size. With pluriStrainer® Maxi, the process can be organized as follows:

  • Start with the largest particles: The first mesh is selected to retain the largest particles in the sample, while smaller particles pass through to the next stage.

  • Move toward finer meshes: Each following stage can use a smaller mesh size to retain progressively smaller particle fractions.

  • Create defined particle fractions: Instead of collecting one mixed fraction, researchers can obtain separate groups of large, medium, and fine particles based on the selected mesh sizes.

  • Build a Lab Strainer cascade: Different pluriStrainer® Maxi mesh sizes can be stacked together to make a Lab Strainer cascade. The exact setup depends on the sample and the particle fractions you want to collect.

  • Use a coarse-to-fine sequence: A common arrangement starts with a mesh to catch large debris. Then come meshes for medium-sized particles and finer particles. This way different size ranges are separated during the workflow.

  • Arrange meshes in the right order: When sorting particles by size place the mesh before the smaller one. This ensures that bigger particles are caught earlier so they do not. Interfere with the finer stages.

  • Manage the load on finer meshes: Starting with a coarse stage helps avoid clogging the fine mesh. Large particles don’t reach the layers. That means the fine mesh can work efficiently on the small fraction it is meant to collect.

  • Handle larger sample volumes: pluriStrainer® Maxi is designed for sample volumes ranging from more than 100 mL to more than 10 L, supporting multi-stage filtration of larger quantities.

  • Support higher flow rates: Its high-flow channel system supports the movement of larger quantities of liquid through the filtration setup.

  • Connect to different bottles: The device can connect to bottles. It works with GL45 bottles and adapters are available for GL32 and GL80 bottle threads. This gives users flexibility when choosing the container for their work.

  • Support controlled sample input: The lid has a tubing port that allows for controlled sample input. This means researchers can refill samples or connect to a low-pressure system when needed. It makes handling the sample easier and more precise.

  • Adapt the complete setup: Multi-stage filtration can be arranged according to how the sample needs to be introduced, filtered, and collected, rather than simply stacking meshes without a defined purpose.

  • Process fractions separately: After filtration finishes we can handle each retained fraction on its own rather than mixing particles that were gathered at different sizes.

  • Match fractions to the research goal: If a sample holds medium and fine particles a three‑stage system can create three matching fractions that we can look at or process on their own.

  • Use size as a separation parameter: This method is especially helpful when the size of the particles matters a lot in the study.

Choosing Mesh Combinations for Different Particle Separation Goals

The effectiveness of a multi-stage filtration setup depends heavily on choosing the right mesh combination. More meshes do not automatically mean better separation. Each stage should have a clear purpose and contribute to the desired particle-size separation.

The pluriStrainer® Maxi has 13 mesh sizes: 5, 20 40 70 100 200 300 400 500 750 1,000 1,400 and 2,000 micrometers. This selection allows researchers to have a lot of options when creating a -step process. The first thing to do is to find out what size particles are in the sample and decide which parts are important for the study. If the sample has big particles, using bigger meshes might be enough. If smaller particles also need to be separated using meshes can help. For example a sample with particles from hundreds of micrometers to a millimeter might need different meshes than a sample with particles between 5 and 100 micrometers. The order of the meshes should show these differences. A researcher who wants to separate medium and small particles could choose three meshes that make clear size groups. The biggest mesh would keep the particles, the next mesh would collect a medium size group and the smallest mesh would keep the smaller particles. The exact set of meshes should be chosen based on what's expected in the sample and what fractions are needed, not just by picking random mesh sizes.

It is also important to consider the amount of material present. A sample with a high concentration of large particles may require a more gradual filtration sequence. Using a fine mesh too early could cause the finer stage to receive more material than it can practically handle. A coarse‑to‑fine sequence can therefore be useful for samples with a range of particle sizes. Larger material is removed first reducing the particle load that reaches the stages. The purpose of the analysis should also guide mesh selection.

In some workflows the researcher may only need to remove unwanted particles before collecting a smaller fraction. In others several particle‑size groups may need to be collected. These two goals require configurations. If one target fraction is important, adding several additional stages may make the workflow more complicated, without providing a clear benefit.

If the objective is to compare particles across different size ranges multiple stages may be justified because each mesh can produce a fraction. Mesh selection should also take analysis into account. Researchers should consider whether the retained material will be examined, microscopically counted, characterized, cultured or subjected to another process. The particle fractions should be large enough. Clearly separated enough to support the intended next step. A selected mesh combination can therefore make the filtration process more predictable. Then treating all particles in the sample as one group researchers can establish defined size ranges and work with them separately. The broad mesh range of pluriStrainer® Maxi makes it possible to adjust this approach for different samples. The same basic device can support a coarse separation in one workflow and a finer multi-stage separation in another.

Where Multi-Stage Filtration Can Improve Particle Separation

Multi-stage filtration can be useful across applications where samples contain particles of different sizes and researchers need more than a single retained fraction.

Environmental Water Analysis

Environmental water samples often have a mix of suspended particles, sediment and biological material along with kinds of particulate matter. To sort these materials using mesh sizes helps divide them into distinct size groups. For water samples the pluriStrainer® Maxi allows processing of more than 100 mL all the way up to over 10 liters. With a -stage setup larger particles are captured first and then smaller fractions are collected step, by step. This method gives researchers a view of how particle populations change across different size ranges. It’s especially helpful when the goal isn’t to remove particles above a certain size but to compare how particles vary in size groups.

Microplastic Analysis

Microplastic studies frequently involve particles that differ greatly in size. A single filtration stage can gather particles across a range, which makes a single filtration stage more difficult to separate different size groups.

A sequence of mesh sizes can split the sample into fractions. Larger particles can be kept at a stage while smaller particles can move toward finer meshes. The approach can help researchers arrange collected material by size before identification or further analysis.

Cell Clusters and Spheroids

Size-based separation is also relevant to biological research. Cell clusters and spheroids can vary in size, and researchers may sometimes need to separate larger clusters from smaller ones. The pluriStrainer® Maxi can be used with different mesh sizes to divide these structures into size fractions. A larger mesh can retain larger clusters while smaller structures continue through to finer meshes. This provides a physical method for separating groups according to size without requiring the sample to be processed through several independent filtration steps.

Separating Particles for Individual Analysis

Multi-stage filtration can also be useful when each particle fraction has a different analytical purpose. Instead of collecting one mixed sample, researchers can work with several fractions generated during the same filtration process. 

For example, one fraction may contain larger material for visual examination, while another may contain smaller particles for additional analysis. Keeping these fractions separate can make comparisons easier and reduce the need to sort mixed material later.

Processing Larger Samples More Efficiently

Large-volume samples can be difficult to process when every size fraction requires a filtration step. A multi-stage setup provides a way to combine size-based separation points into one arrangement. The pluriStrainer® Maxi is designed for volumes and includes features that support practical sample handling. The high-flow channel system of pluriStrainer® Maxi helps support flow rates while the tubing port can be used for sample refilling or connection to a low-pressure system. For laboratories processing repeated samples a configurable setup can make workflows easier to standardize. Researchers can establish a mesh sequence for a particular type of sample and use the same arrangement when comparable samples need to be processed. The key benefit is control over the particle fractions. Instead of asking only whether a particle passed through or was retained, multi-stage filtration provides more information about where particles fall within the selected size ranges.

Conclusion

Samples that have particles of different sizes can be hard to separate using just one mesh. A single filtration step might hold on to a mix of particle sizes, which means scientists still have to do work to sort them out. Multi-stage filtration is a way. By putting mesh sizes one after another particles can be separated step by step. Big particles get caught on and small ones move through to the smaller meshes.

The pluriStrainer® Maxi works this way by having 13 mesh sizes that go from 5 micrometers to 2,000 micrometers. Scientists can. Mix the meshes depending on what is in their sample and what particle sizes they want to collect. Putting the devices on top of each other creates a Lab Strainer cascade. This setup allows many filtration steps to happen in one go. This method is useful for analyzing water. It is also useful for studying microplastics. It is also useful for working with samples. These samples can have cell clusters or spheroids. It is also useful when different particle sizes need to be gathered for more testing.

The best way to set things up is not always the one with the filters. Instead every part of the process should have a goal. Start with the size of the particles you expect, figure out which parts are important and then choose the filter sizes. This can make the whole process easier to handle. For samples the pluriStrainer® Maxi offers more options because it can hold a lot of material connected to bottles, has a system that lets liquid move quickly and has a place to add tubes. All these parts let scientists create filtering methods that work well for both the size of the particles and the amount of sample they are working with.

By changing one step of filtering into a series of steps based on size, multi-stage filtering can help scientists have more control over what stays, what goes through and which parts of the particles are left for more work.